跳至内容
中文

Dielectric strength

Dielectric strength is how much voltage a material can block before it breaks down. Learn how it is tested and why thickness matters.

阅读约 3 分钟 · 更新于 October 11, 2026 · 数据实时来自我们的材料数据库。

What it means in practice

Dielectric strength is the electric field an insulating material can withstand before current punches through it. Above that point the material breaks down, often leaving a tiny burnt channel, and stops insulating.

Key takeaways

  • Dielectric strength is the electric field an insulator withstands before current punches through.
  • Thin samples read higher per mm, so compare values at similar thickness.
  • Printed walls with voids usually insulate less well than moulded test plaques.
  • A dielectric value alone does not make a design safe; test the finished part.
Resins17.9 kV/mm典型值 · 范围 15–37 · 15 种材料
Filaments19.75 kV/mm典型值 · 范围 6.05–172 · 6 种材料
Powders27 kV/mm典型值 · 范围 4.38–42 · 5 种材料

It matters for printed parts that separate live conductors from each other or from people:

  • Insulating spacers, bushings and standoffs.
  • Housings for power supplies, battery packs and chargers.
  • Coil formers and bobbins.
  • Test fixtures and probe holders that touch high-voltage circuits.

Watch out

Conductive and ESD-safe materials are the opposite. They are not insulators and should not be used where insulation is needed.

How it’s measured

A flat sample sits between two electrodes, often under oil to stop sparks running around the edge. The voltage is raised until the sample breaks down. The breakdown voltage divided by the sample thickness gives the dielectric strength.

  • Standards: IEC 60243-1 and ASTM D149. Both allow a quick, steady ramp (short-time method) or slower step-by-step methods.
  • Units: kV/mm. US sheets often use volts per mil; 1 kV/mm is about 25.4 V/mil.

How to read and compare it

  • Thickness changes the number. Thin samples usually give a higher kV/mm than thick ones. Doubling wall thickness does not double the voltage a part can block. Compare values measured at similar thickness.
  • Method and conditions. Short-time tests give higher values than slow step tests. AC and DC results differ. Humidity, temperature and the surrounding medium also matter.
  • Printed parts have voids. Gaps between extrusion lines and layers can hold air, which breaks down more easily than solid plastic. Printed walls usually insulate less well than a moulded test plaque. Use 100% infill and generous wall thickness for insulating parts.
  • Moisture. Water-absorbing materials such as nylon lose insulation as they take up moisture.
  • Not the whole story. Electrical safety also depends on creepage and clearance distances, tracking resistance and flammability. A dielectric value alone does not make a design safe. Follow the safety standard for your product and test the finished part.

Range in our catalog

Few datasheets report dielectric strength, so the sample is small.

  • All materials: 4.38–172 kV/mm (中位数 19.75 kV/mm,共 26 种材料)
  • Resins: 15–37 kV/mm (中位数 17.9 kV/mm,共 15 种材料)
  • Powders (SLS and MJF): 4.38–42 kV/mm (中位数 27 kV/mm,共 5 种材料)
  • Engineering materials: 7.6–42 kV/mm (中位数 28 kV/mm,共 14 种材料)
Dielectric strength by material form (kV/mm)
  1. 树脂 1515–37
  2. 线材 66.05–172
  3. 粉末 54.38–42

色条 = 最低至最高,圆点 = 中位数。共 26 种材料,数据实时来自我们的数据库。

Highest and lowest in our catalog

Highest dielectric strength

材料聚合物介电强度
3D4Makers PI Z2PI172 kV/mm
Ultrasint PP 1400 BlackPP42 kV/mm
Ultracur3D RG 35Photopolymer37 kV/mm
Ultracur3D SLA 7700Photopolymer34 kV/mm
Ultrafuse PC/ABS FR BlackPC/ABS33 kV/mm

Lowest dielectric strength

材料聚合物介电强度
Ultrasint TPU 01TPU4.38 kV/mm
Fiberon PPS-GF20PPS6.05 kV/mm
HP 3D HR PA 12 FRPA127.6 kV/mm
Formfutura PPSUPPSU15 kV/mm
Somos WaterClear Ultra 10122Photopolymer15 kV/mm

Tip

Check the thickness and method on each datasheet before ranking materials by these values.